Images shown are for illustration purposes only.
The final building may differ based on colour choice, door locations, selected upgrades, and local building requirements.
30X60X16 Commercial Steel Building Kit – Insulated Facility
The 30×60×16 Commercial Steel Building Kit – Insulated Facility is a prefabricated structural steel building system designed to provide enclosed commercial space with insulated building envelope capability within a clear-span rigid-frame configuration. This column-free structure supports temperature-controlled environments, equipment accommodation, and operational workspace planning within a compact commercial footprint. Supplied as a packaged steel building kit including structural framing, insulated panel systems or insulation-ready cladding, hardware, and printed structural documentation for permitting reference where required.
Product Classification
Prefabricated structural steel building kit
Commercial accessory or operational structure
Pre-Engineered Metal Building (PEMB) system
Physical packaged building materials shipped by freight
Product classification: Prefabricated commercial insulated steel building kit
Technical Specifications (Quick Reference)
Building Width: 30 ft
Building Length: 60 ft
Wall Height: 16 ft
Interior Area: 1,800 sq ft
Clear Interior Height at Eave: approx 16 ft
Peak Interior Height: varies by roof pitch (gable configuration)
Roof Pitch: project-specific configuration
Structural System: Rigid-frame portal PEMB
Interior Span: Column-free primary structural frame
Panel System: Profiled steel cladding or insulated panel envelope
Panel Profile Type: Ribbed structural cladding or composite insulated panels
Connection Method: Bolted structural assembly
Field Assembly: Mechanical fastener installation
Intended Use Category: Enclosed commercial building structure with insulated envelope capability
Structural Design Basis:
Final structural configuration is determined based on confirmed installation location, environmental loading, exposure classification, importance category, and applicable building code requirements.
Product Overview
The 30×60 insulated configuration provides enclosed commercial workspace with thermal control capability within a compact clear-span structural system.
This format is commonly evaluated when commercial operations require controlled interior conditions for equipment protection, product storage, or year-round operational use within a moderate building footprint.
The 30-foot structural span supports unobstructed interior layout planning, while the 60-foot building length allows functional separation between work zones, storage areas, and equipment placement.
The 16-foot wall height supports vertical clearance requirements for equipment access, mechanical systems, and interior workspace planning.
As a rigid-frame prefabricated steel building system with insulated envelope capability, the structure supports temperature moderation, condensation control planning, and enclosed commercial operations.
This prefab insulated metal commercial building is frequently evaluated for workshops, service facilities, equipment storage environments, and commercial operations requiring controlled interior conditions across Canadian climates.
Structural System Classification
Pre-Engineered Metal Building (PEMB)
Rigid-frame portal structural system
Clear-span primary structural frame
Rigid frame geometry transfers roof and lateral loads through structural columns into foundation bearing points. Portal frame action develops moment resistance at column-rafter connections, allowing wide spans without intermediate interior supports.
Span-to-height proportions are configured to maintain structural efficiency and enclosed volume performance suitable for commercial insulated building applications.
The structural system is designed as a prefabricated rigid-frame enclosure commonly used for commercial facilities requiring enclosed environmental control.
Portal frame action develops moment resistance at column-rafter connections characteristic of portal frame geometry.
Structural Components & Materials
Primary structural framing fabricated from structural steel members with prefabricated connection plates for bolted field assembly.
Exterior building envelope may utilize insulated metal panels or insulation-ready cladding systems attached to secondary framing members using mechanical fasteners.
Steel panel systems utilize protective coating finishes appropriate for exterior building envelope applications.
Secondary framing members transfer enclosure loads to primary structural frames while maintaining building envelope stiffness and panel support alignment.
Primary rigid frames are spaced according to structural design requirements determined at time of order to align with applicable building code criteria.
Primary rigid frames are designed to resist bending moments at column-rafter connections characteristic of portal frame geometry.
Structural loads are transferred through rigid frame columns to foundation bearing points. Foundation design must support vertical loads, lateral loads, and concentrated column base reactions generated by rigid-frame structural geometry.
Structural Load Determination Process
Structural loads are determined based on confirmed installation location, applicable building code requirements, environmental loading, and building use classification.
Wind loading considers exposure classification, terrain effects, and importance category based on building function.
Documentation references general Canadian snow and wind load considerations commonly associated with this product type.
Final structural configuration is prepared at time of order based on project location and governing building regulations.
Building Code Alignment
Final structural configuration is prepared to align with applicable provincial and municipal building code requirements based on confirmed installation location.
Use classification, permitting requirements, insulation performance requirements, and foundation design are determined by the authority having jurisdiction.
Size-Specific Performance Advantage
The 30-foot clear span supports unobstructed commercial workspace within a compact structural width.
The 60-foot building depth allows functional separation between work zones, storage areas, and equipment placement.
The 16-foot wall height supports mechanical systems, insulated envelope installation, and vertical workspace planning.
This configuration provides enclosed commercial workspace with thermal control capability while maintaining moderate site coverage.
Interior Clearance Planning
Clear interior height affects equipment clearance, mechanical installation, insulated panel placement, and vertical operational planning.
Usable vertical clearance is reduced by roof structural depth, lighting systems, mechanical systems, and interior installations.
Vertical clearance planning should be evaluated prior to equipment installation.
Interior Usable Space Planning
Interior usable dimensions vary depending on wall system thickness, structural framing depth, insulation system selection, and door configuration.
Actual usable interior width and length are reduced by wall assemblies and structural members.
Circulation pathways for equipment movement, work areas, and storage layout should be planned before fixed installations.
Building Dimension Classification
Nominal building dimensions describe exterior structural footprint.
Actual finished exterior dimensions and interior clearances vary depending on panel profile, insulation system thickness, framing depth, trim systems, and foundation interface.
Interior usable width and length are typically reduced by wall system thickness and structural framing depth.
Final as-built dimensions are confirmed in structural drawings supplied with the building kit.
Authority Planning Insight
This size is commonly planned when commercial operations require insulated enclosed workspace without expanding into large industrial building formats.
It is frequently selected where moderate interior space must support temperature-sensitive equipment, controlled storage environments, or year-round operational activity.
Within commercial building scale progression:
20×40 → compact commercial enclosure
30×60 → insulated operational facility
40×80 → expanded commercial building
60×100 → large operational facility
Insulation & Thermal Envelope Planning
Thermal performance depends on insulation system type, installation method, air sealing, and ventilation design.
Insulated panel systems or interior insulation assemblies are selected based on project-specific environmental control requirements.
Thermal envelope design must coordinate with moisture control and ventilation planning.
Slab & Floor Load Planning
Interior slab design must account for equipment loads, storage systems, vehicle loads, and concentrated point loading where applicable.
Floor structural capacity is determined separately based on operational requirements.
Foundation design must support concentrated structural column reactions and distributed floor loading.
Openings Coordination
Door openings, service penetrations, and mechanical openings must be coordinated with structural frame spacing and load distribution.
Opening placement must be confirmed during project planning.
Lateral Stability System
Building lateral stability is achieved through portal frame action, roof diaphragm behaviour, and bracing elements configured within the structural system.
These components resist wind forces and maintain structural stability.
Delivered Package Description
Building components are delivered in packaged steel sections prepared for offloading and staged assembly at the installation site.
Delivered materials typically include:
- prefabricated primary structural members
- secondary framing components
- steel panel or insulated panel systems
- hardware and fastening systems
- labeled assembly components
- printed structural documentation
Shipment consists of bundled steel components.
Total shipment weight varies by configuration and is confirmed prior to dispatch.
Assembly Complexity
Commercial building installation typically requires coordinated project planning and contractor-performed assembly.
Assembly complexity level: moderate to advanced.
Typical project sequence includes site preparation, foundation construction, delivery coordination, and structural erection.
Lifecycle & Durability Context
Service life depends on coating system performance, insulation system performance, enclosure integrity, foundation stability, environmental exposure, and maintenance practices.
Steel enclosure systems of this scale are commonly selected for long-term commercial infrastructure rather than temporary accessory structures.
Manufacturing & Fabrication Standards
Structural steel components are fabricated using standardized manufacturing processes for prefabricated building systems.
Components are produced for mechanical assembly using prefabricated connection geometry and labeled structural members.
Protective exterior coating systems are applied to cladding components to support exterior building envelope function.
Condensation & Ventilation Planning
Condensation control depends on site climate conditions, insulation design, interior usage patterns, and ventilation strategy.
Ventilation systems and moisture control planning must be coordinated with insulation installation.
Proper condensation management planning is recommended for insulated steel structures in Canadian climates.
Structural Safety & Anchoring Considerations
Building performance depends on proper foundation design, anchoring, erection procedures, and compliance with supplied structural documentation.
Installation must follow accepted construction practices and applicable building regulations.
Foundation design must support concentrated structural loads and anchoring forces.
What’s Included
Structural steel framing components
Steel wall and roof panels or insulated panel systems
Hardware and fastening systems
Printed structural documentation
What’s Not Included
Foundation construction
Installation labor
Mechanical systems
Interior finishing
Electrical systems
Typical Optional Components (Not Included)
Overhead doors
Service doors
Insulation upgrades
Ventilation systems
Interior liner panels
Mechanical system integration
Optional components selected separately.
Freight Delivery Explanation
Building components are shipped by freight as packaged steel materials.
Unloading equipment and staging space must be arranged by the buyer.
Delivery scheduling coordinated prior to shipment.
Site Planning Considerations
Foundation design
Setback requirements
Thermal envelope planning
Delivery vehicle access
Assembly staging area
Municipal permitting requirements
Application Classification
Typical use classification: enclosed commercial building with insulated envelope for operational or storage use.
Use category and occupancy classification determined by the authority having jurisdiction.
Structural Responsibility Statement
Building performance depends on proper foundation design, anchoring, erection procedures, insulation installation, and compliance with supplied structural documentation.
Product Scope Notice
This product is a physical prefabricated steel building kit shipped by freight.
No installation, construction, consulting, or labor services are provided.
Ownership transfers to the buyer upon shipment.
This listing is for packaged building materials only and does not represent a constructed structure.
Canadian Performance Context
Structural documentation references general Canadian snow and wind load considerations commonly associated with this product type.
Insulated steel enclosure construction supports temperature moderation and protection from seasonal weather conditions typical across Canadian commercial environments.
Decision Summary
Choose this size if you need:
- insulated commercial workspace
- controlled interior environment
- moderate building footprint
- unobstructed interior layout
Consider larger structures if:
- high-capacity operations required
- large equipment storage required
- multi-zone industrial processes planned
Only logged in customers who have purchased this product may leave a review.
















Reviews